01What Is a Stair Tower and How Does It Differ from a Ladder?
A stair tower is a temporary access structure built from scaffold components, containing stair flights with steps and guardrails. We build our tower, which we call Ringscaff-ST, from the Ringscaff ringlock scaffolding components we manufacture in our factory.
The cheapest way to get up on a site is a ladder leaning against a wall. The problem is the way a ladder forces people to use it. The construction rules of OSHA, the US occupational safety authority, require the user to face the ladder, to keep at least one hand on the ladder when climbing up and down, and not to carry any load that could cause loss of balance. In short, a ladder carries only one person at a time, largely empty-handed.
In a stair tower, by contrast, the steps are wide, there are guardrails on both sides of the flights and there is a landing at the end of every flight. Workers walk facing the direction they are going, can carry their tools or small materials, and can stop on a landing when tired. The access clause of the same rules requires a stairway or ladder at every change in level of 48 cm or more where there is no ramp or personnel hoist. As the number of floors and people increases, it becomes obvious which of the two options fits. In Türkiye too, the Ministry's leaflet on safe facade scaffolding recommends reaching every level of a scaffold by a suitable stair.
Our product manual has a separate rule for the top of the tower: above the level of the highest access platform, the scaffold is raised by a further 1.00 m and horizontal guardrails are fitted to the uprights. This way there is a guardrail in front of the worker at the point where the tower ends as well.
02How Many People Can Use It at the Same Time?
The capacity of a working scaffold is expressed as the load per square metre. With a stair tower, the real question is how many people will be on the stairs at the same time. The structural calculation in our product manual is based on these assumptions:
These two limits are read together. No more than three people should gather on a flight: the fourth person waits on the landing until the flight ahead is clear. But the total load the tower can carry is also limited. A 60 m tower has about 30 stair flights; if three people climbed onto every one, there would be 90 people on the tower, roughly 9 tonnes of people. The structural calculation is not made for that: on a 60 m tower, do not exceed 18-20 people in total at the same time. That is why not all flights are used fully at once; at peak times people enter in turn.
60 m is the height of the standard arrangement in our manual. Taller towers and more intensive use are built to a project-specific structural calculation.
Shift changes, lunch breaks or the start of a concrete pour, when crews go up and down at the same time, are the busiest moments for the tower. For sites with heavy personnel traffic, our manual specifies an additional measure: reinforced ledgers are used instead of the standard 1.448 m ledgers on which the stairs are hung. Where even more people will use the tower at the same time, we recalculate the system with our technical team and change the tower arrangement if necessary.